The codes and guides behind DeckCrazy’s drawings, and what Denver and the counties around it ask for in a deck permit. A design here is a starting sketch: your builder and your building department confirm the details for your yard.
The standard step-by-step reference for building a wood deck to code: joists, beams, posts, footings, ledger attachment, guards and stairs, with span tables.
DeckCrazy's framing comes from it: joist spans (Table 2), beam sizes (Table 3A), footing sizes and post heights (Table 4), and its stair and guard rules.
Publisher of DCA 6 and the wood design standards the building codes reference; check here for newer editions and errata.
The International Residential Code (IRC) is the model code most US cities adopt for houses and decks, often with local changes. The ICC lets anyone read it free online.
Deck rules in the code itself: footings, posts, beams, joists, decking, ledger attachment and lateral load connections.
Stair rise and run, handrails, landings, and guards (railings) for any walking surface more than 30 inches above the ground.
Footing size and depth, including going below the frost line.
The newest edition, and the one Denver's current code is based on (below). Same chapters: decks in Chapter 5, stairs and guards in Chapter 3.
When you need a permit: a zoning permit for uncovered decks 12 inches or more off the ground, and a building permit too at 30 inches or more; covered structures need both.
Denver enforces the 2025 Denver Building and Fire Codes (effective December 31, 2025), based on the 2024 I-codes with Denver's amendments.
For homes in unincorporated Jefferson County: 2024 International Residential Code with the Jefferson County supplement (permits applied for after June 30, 2026). Footings at least 36 in deep. Decks are designed for 40 psf live load or the roof snow load for the property's elevation, whichever is greater: 30 psf below 6,500 ft, 40 psf at 7,125 ft, more above (Jefferson County snow load chart). Cities and towns in the county run their own permits.
What plans must show: site plan, framing, elevations, stair sections, design criteria, and when an engineer’s stamp is needed.
Ground and roof snow loads by elevation: 30 psf roof snow below 6,500 ft, rising with elevation.
The county’s changes to the 2024 IRC: 36 in frost depth, and decks designed for 40 psf or the roof snow load, whichever is greater.
For homes in unincorporated Douglas County: The codes Douglas County adopted July 1, 2026 (the 2024 International codes, with county amendments). Footings at least 36 in deep. Ground snow load equals roof snow load (no reductions), by elevation: 30 psf from 5,152 to 5,999 ft, rising to 70 psf at 9,500 ft and above. Cities and towns in the county run their own permits.
How to apply for a deck permit in unincorporated Douglas County.
The county’s deck Building Guide: details to check, plot plan contents, 36 in footings, guards, stairs, ledger flashing.
Adopted codes (effective July 1, 2026), snow load by elevation, 36 in frost depth, wind speeds.
For homes in unincorporated Arapahoe County: 2021 International Residential Code with Arapahoe County amendments (in effect since April 1, 2022; the county says its instructions are being updated). Cities and towns in the county run their own permits.
Requirements for an uncovered deck permit and the county’s Amended ICC Deck Building Guide; owner-built permits need a signed certificate.
Contacts, adopted codes and permit instructions for unincorporated Arapahoe County.
Required before digging footing holes, however small the job: ask at least two full business days ahead and buried utility lines get marked for free. Private lines (sprinklers, a gas line to a grill) aren't marked.
Start a request online, or call 811.
When each Denver-area city and county asks for a permit, and what to have ready.